UV Bank with Ozone Generation System
Add-on UV and ozone module installed after the IVOLTAIR ESP for odour removal and air disinfection. Five models, up to 660 µW/cm² UV output.
- Treatment
- Dual action: UV irradiation and ozone oxidation in one module
- Max UV output
- 660 µW/cm² (IV15200UV)
- Rated lamp life
- 10,000 hours
Technical specification
| Series | IV-UV (datasheet IVA-DS-UV-01) |
|---|---|
| Treatment | Dual action: UV irradiation and ozone oxidation in one module |
| Max UV output | 660 µW/cm² (IV15200UV) |
| Rated lamp life | 10,000 hours |
| Control unit | Digital timer with run-hours display for planned lamp replacement |
| Operator interface | “UV ON” blue LED indication |
| Lamps and ballasts | Lamps to IS 2418, ballasts to IS 13021, CE-compliant HV supply |
| Installation | Downstream of an IVOLTAIR ESP section |
| Application | Odour removal and air disinfection |
Models
| Parameter | IV2500UV | IV5000UV | IV7600UV | IV10200UV | IV15200UV |
|---|---|---|---|---|---|
| UV lamp wattage | 40 W × 2 | 130 W × 2 | 130 W × 2 | 130 W × 2 | 130 W × 6 |
| Number of UV lamps | 2 | 2 | 2 | 2 | 6 |
| Total UV lamp power | 80 W | 260 W | 260 W | 260 W | 780 W |
| UV output (µW/cm²) | 115 | 420 | 420 | 420 | 660 |
| Ozone output (g/h)* | 1.24 | 4.2 | 4.2 | 8.4 | 12.6 |
| Pairs with ESP | IV2500 | IV5000 | IV7600 | IV10200 | IV15200 |
* Ozone output at standard conditions. Total UV lamp power is the sum of rated lamp wattages. Each model is sized to sit directly after the matching IVOLTAIR ESP.
How it works
- Pre-filtration (ESP): smoke, grease and particulate matter are captured in the upstream electrostatic precipitator.
- UV irradiation: the cleaned air passes banks of UV lamps that inactivate airborne micro-organisms.
- Ozone oxidation: ozone produced by the lamps oxidises odour-causing compounds in the duct before discharge.
Safety
- UV radiation and ozone are hazardous to eyes and skin. Never look at energised lamps.
- Isolate the electrical supply before opening any access door or panel.
- Allow residual ozone to disperse before entering the cabinet or duct.
- Installation and servicing by qualified personnel only.
Maintenance
- Monitor lamp hours on the run-hours display and replace lamps at 10,000 hours.
- Keep lamp surfaces clean to maintain rated UV output.
- Check the “UV ON” indication during routine inspection.
- Use only genuine IVOLTAIR replacement lamps and ballasts.
Use it with
Activated Carbon V BankBolt-on odour and VOC control sized to match every IVOLTAIR ESP model.
Ventilation Ecology UnitA complete treatment train in one double-skin housing: ESP, F7 bag filter, carbon, UV and fan, with PLC control.
IV15200Six-cell, highest-capacity ESP for central kitchens, food plants and heavy industrial exhaust.