IV2500 / 1V2500UV
UV Details
UV LAMP WATTAGE – 40W * 02
UV OUTPUT – 115 micro watt/sqcm
OZONE OUTPUT – 1.24 Grams/hour ( at standard conditions)
RATED LIFE – 10000 HOURS
CONTROL UNIT – DIGITAL TIMER WITH RUN HOURS DISPLAY
OPERATOR INTERFACE – UV ON BLUE LED INDICATION
Technical Specifications
DIMENSIONS (mm) – H515* W695* L720
METAL OF CONSTRUCTION – MS CRCA 1.6MM
FINISHING – 7 TANK PROCESSED, INDUSTRIAL GREY POWDER COAT
ELECTRICAL PARAMETERS – 110 – 220V AC, 50HZ, 50WATTS MAX
HIGH VOLTAGE –
DUAL OUTPUT PWM TECHNOLOGY POWER SUPPLY UNIT
SHORT CIRCUIT, ARC PROTECTION & AUTO RESET 1.0 SECOND RECOVERY TIME.
CE CERTIFIED POWER SUPPLY UNIT.
SAFETY FEATURES – DOOR SAFETY SWITCH INTEGRATED, EARTH LEAK TRIP.
AIR VOLUME – 1500-2000 CFM (1750-2340 CMH)
PARTICLE CAPTURE RANGE – 0.01MICRON METER – 10 MICRON METER
MAXIMUM EFFICIENCY –
95% DOP SINGLE PASS TEST
97% DOP DOUBLE PASS TEST
COMPLIES ANSI/ASHRAE 52.2-2017 STANDARD TEST PROCEDURE
ESP CELL TECHNOLOGY – DUAL STAGE (IONIZER & COLLECTOR)
Number of Cells – 1
MESH FILTERS – 01 OF ALUMINIUM MESH WITH SS304 FRAME
BMS CONNECTIVITY – NO VOLT RELAY FOR BMS MONITORING / ALARM INTEGRATION
OPERATOR INTERFACE –
GREEN LED – HEALTHY
RED LED – CLEAN / MAINTENANCE
POWER ON/OFF SWITCH
AC PROTECTION FUSE
INSTALLATION TYPE – CEILING SUSPENDED, FLOOR AND STAND MOUNT.
Download Datasheet
Additional Information
- COMPLIES ASHRAE 50.2-2017 STANDARD FOR FILTER EFFICIENCY TEST
- COMPLIES NFPA96 SAFETY STANDARD FOR VENTILATION APPLICATION
- COMPLIES NFPA79 ELECTRICAL STANDARD
- COMPLIES IS2418 STANDARD FOR UV LAMPS
- COMPLIES IS13021 STANDARD FOR UV BALLAST
- COMPLIES CE STANDARD FOR HIGH VOLTAGE POWER SUPPLY
IV5000 / IV5000UV
UV Details
UV LAMP WATTAGE – 75W * 02
UV OUTPUT – 230 micro watt/sqcm
OZONE OUTPUT – 2.42 Grams/hour ( at standard conditions)
RATED LIFE – 10000 HOURS
CONTROL UNIT – DIGITAL TIMER WITH RUN HOURS DISPLAY
OPERATOR INTERFACE – UV ON BLUE LED INDICATION
Technical Specifications
Download Datasheet
Additional Information
- COMPLIES ASHRAE 50.2-2017 STANDARD FOR FILTER EFFICIENCY TEST
- COMPLIES NFPA96 SAFETY STANDARD FOR VENTILATION APPLICATION
- COMPLIES NFPA79 ELECTRICAL STANDARD
- COMPLIES IS2418 STANDARD FOR UV LAMPS
- COMPLIES IS13021 STANDARD FOR UV BALLAST
- COMPLIES CE STANDARD FOR HIGH VOLTAGE POWER SUPPLY
IV7600 / IV7600UV
UV Details
UV LAMP WATTAGE – 130W * 02
UV OUTPUT – 420 micro watt/sqcm
OZONE OUTPUT – 4.2 Grams/hour ( at standard conditions)
RATED LIFE – 10000 HOURS
CONTROL UNIT – DIGITAL TIMER WITH RUN HOURS DISPLAY
OPERATOR INTERFACE – UV ON BLUE LED INDICATION
Technical Specifications
DIMENSIONS (mm) – H515*W695*L1850
METAL OF CONSTRUCTION – MMS CRCA 1.6MM
FINISHING – 7 TANK PROCESSED, INDUSTRIAL GREY POWDER COAT
ELECTRICAL PARAMETERS – 110 – 220V AC, 50HZ, 150WATTS MAX
HIGH VOLTAGE –
DUAL OUTPUT PWM TECHNOLOGY POWER SUPPLY UNIT
SHORT CIRCUIT, ARC PROTECTION & AUTO RESET 1.0 SECOND RECOVERY TIME.
CE CERTIFIED POWER SUPPLY UNIT.
SAFETY FEATURES – DOOR SAFETY SWITCH INTEGRATED, EARTH LEAK TRIP.
AIR VOLUME – 4500 CFM – 6000 CFM (5260 – 7020 CMH)
PARTICLE CAPTURE RANGE – 0.01 MICRON METER – 10 MICRON METER
MAXIMUM EFFICIENCY –
95% DOP SINGLE PASS TEST
97% DOP DOUBLE PASS TEST
COMPLIES ANSI/ASHRAE 52.2-2017 STANDARD TEST PROCEDURE
ESP CELL TECHNOLOGY – DUAL STAGE (IONIZER & COLLECTOR)
Number of Cells – 3
MESH FILTERS – 03 OF ALUMINIUM MESH WITH SS304 FRAME
BMS CONNECTIVITY – NO VOLT RELAY FOR BMS MONITORING / ALARM INTEGRATION
OPERATOR INTERFACE –
GREEN LED – HEALTHY
RED LED – CLEAN / MAINTENANCE
POWER ON/OFF SWITCH
AC PROTECTION FUSE
INSTALLATION TYPE – CEILING SUSPENDED, FLOOR AND STAND MOUNT.
Download Datasheet
Additional Information
- COMPLIES ASHRAE 50.2-2017 STANDARD FOR FILTER EFFICIENCY TEST
- COMPLIES NFPA96 SAFETY STANDARD FOR VENTILATION APPLICATION
- COMPLIES NFPA79 ELECTRICAL STANDARD
- COMPLIES IS2418 STANDARD FOR UV LAMPS
- COMPLIES IS13021 STANDARD FOR UV BALLAST
- COMPLIES CE STANDARD FOR HIGH VOLTAGE POWER SUPPLY
IV10200 / IV10200UV
UV Details
UV LAMP WATTAGE – 130W * 04
UV OUTPUT – 420 micro watt/sqcm
OZONE OUTPUT – 8.4 Grams/hour ( at standard conditions)
RATED LIFE – 10000 HOURS
CONTROL UNIT – DIGITAL TIMER WITH RUN HOURS DISPLAY
OPERATOR INTERFACE – UV ON BLUE LED INDICATION
Technical Specifications
DIMENSIONS (mm) – H515*W695*L2410
METAL OF CONSTRUCTION – MS CRCA 1.6MM
FINISHING – 7 TANK PROCESSED,INDUSTRIAL GREY POWDER COAT
ELECTRICAL PARAMETERS – 110 – 220V AC, 50HZ, 200WATTS MAX
HIGH VOLTAGE –
DUAL OUTPUT PWM TECHNOLOGY POWER SUPPLY UNIT.
SHORT CIRCUIT, ARC PROTECTION & AUTO RESET 1.0 SECOND RECOVERY TIME.
CE CERTIFIED POWER SUPPLY UNIT.
SAFETY FEATURES – DOOR SAFETY SWITCH INTEGRATED, EARTH LEAK TRIP.
AIR VOLUME – 6000 CFM – 8000 CFM (7020 CHM – 9360 CMH)
PARTICLE CAPTURE RANGE – 0.01 MICRON METER – 10 MICRON METER
MAXIMUM EFFICIENCY –
95% DOP SINGLE PASS TEST
97% DOP DOUBLE PASS TEST
COMPLIES ANSI/ASHRAE 52.2-2017 STANDARD TEST PROCEDURE
ESP CELL TECHNOLOGY – DUAL STAGE (IONIZER & COLLECTOR)
Number of Cells – 4
MESH FILTERS – 04 OF ALUMINIUM MESH WITH SS304 FRAME
BMS CONNECTIVITY – NO VOLT RELAY FOR BMS MONITORING / ALARM INTEGRATION
OPERATOR INTERFACE –
GREEN LED – HEALTHY
RED LED – CLEAN / MAINTENANCE
POWER ON/OFF SWITCH
AC PROTECTION FUSE
INSTALLATION TYPE – CEILING SUSPENDED, FLOOR AND STAND MOUNT.
Download Datasheet
Additional Information
- COMPLIES ASHRAE 50.2-2017 STANDARD FOR FILTER EFFICIENCY TEST
- COMPLIES NFPA96 SAFETY STANDARD FOR VENTILATION APPLICATION
- COMPLIES NFPA79 ELECTRICAL STANDARD
- COMPLIES IS2418 STANDARD FOR UV LAMPS
- COMPLIES IS13021 STANDARD FOR UV BALLAST
- COMPLIES CE STANDARD FOR HIGH VOLTAGE POWER SUPPLY
IV15200 / IV15200UV
UV Details
UV LAMP WATTAGE – 130W * 04
UV OUTPUT – 660 micro watt/sqcm
OZONE OUTPUT – 12.6 Grams/hour (at standard conditions)
RATED LIFE – 10000 HOURS
CONTROL UNIT – DIGITAL TIMER WITH RUN HOURS DISPLAY
OPERATOR INTERFACE – UV ON BLUE LED INDICATION
Technical Specifications
DIMENSIONS (mm) – H1030*696*L1865
METAL OF CONSTRUCTION – MS CRCA 1.6MM
FINISHING – 7 tank processed,industrial grey powder coat
ELECTRICAL PARAMETERS – 110 – 220V AC, 50HZ, 200 WATTS MAX
HIGH VOLTAGE –
Dual output PWM technology power supply unit short circuit, arc protection and
auto reset 1.0 Second recovery time CE certified power supply unit
SHORT CIRCUIT, ARC PROTECTION & AUTO RESET 1.0 SECOND RECOVERY TIME.
CE CERTIFIED POWER SUPPLY UNIT.
SAFETY FEATURES – DOOR SAFETY SWITCH INTEGRATED, EARTH LEAK TRIP.
AIR VOLUME – 9000 CFM – 13500 CFM MAX (15300 CMH – 22950 CMH MAX)
PARTICLE CAPTURE RANGE – 0.1 Micron Meter – 10 Micron Meter
MAXIMUM EFFICIENCY –
95% DOP single pass test
97% DOP double pass test complies ANSI / ASHRAE 52.2-2017 standard test procedure
COMPLIES ANSI/ASHRAE 52.2-2017 STANDARD TEST PROCEDURE
ESP CELL TECHNOLOGY – DUAL STAGE (IONIZER & COLLECTOR)
Number of Cells – 6
MESH FILTERS – 06 of aluminum mesh with SS304 frame
BMS CONNECTIVITY – NO VOLT RELAY FOR BMS MONITORING / ALARM INTEGRATION
OPERATOR INTERFACE –
GREEN LED – HEALTHY
RED LED – CLEAN / MAINTENANCE
POWER ON/OFF SWITCH
AC PROTECTION FUSE
INSTALLATION TYPE – CEILING SUSPENDED, FLOOR AND STAND MOUNT.
Download Datasheet
Additional Information
- COMPLIES ASHRAE 50.2-2017 STANDARD FOR FILTER EFFICIENCY TEST
- COMPLIES NFPA96 SAFETY STANDARD FOR VENTILATION APPLICATION
- COMPLIES NFPA79 ELECTRICAL STANDARD
- COMPLIES IS2418 STANDARD FOR UV LAMPS
- COMPLIES IS13021 STANDARD FOR UV BALLAST
- COMPLIES CE STANDARD FOR HIGH VOLTAGE POWER SUPPLY
ECOLOGY UNIT
UV Details
UV LAMP WATTAGE – 40W – 130 WATTS
OZONE OUTPUT – 1.26 – 8.4 Grams/hour ( at standard conditions)
RATED LIFE – 10000 HOURS
CONTROL UNIT – DIGITAL TIMER WITH RUN HOURS DISPLAY
OPERATOR INTERFACE – UV ON BLUE LED INDICATION
Technical Specifications
DIMENSIONS (mm) – CUSTOM DESIGNED ACCORDING TO THE DEMAND
METAL OF CONSTRUCTION – MS CRCA 1.6MM
FINISHING – 7 TANK PROCESSED
ELECTRICAL PARAMETERS – 3PH NEUTRAL SYSTEM , 0.75KW – 7.5KW POWER
AIR VOLUME – 1500 CFM – 6500 CFM MAX (2550 CHM – 11050CMH MAX)
ESP CAPACITY –
1500CFM – 6000 CFM ( AS PER DEMAND) .
DUAL VOLTAGE PWM TECH POWER SUPPLY, SHORT CIRCUIT, ARC PROTECTION & AUTO RESET 1.0 SECOND RECOVERY TIME .
CE CERTIFIED POWER SUPPLY UNIT .
SAFETY FEATURES – DOOR SAFETY SWITCH, PRESSURE SWITCH INTEGRATED .
STATIC PRESSURE – 10MM WG FOR CLEAN UNIT, 15MM WG FOR CHOCKED UNIT
Particle Capture Range – 0.01 MICRON METER – 10 MICRON METER
MAXIMUM EFFICIENCY –
96% DOP SINGLE PASS TEST
99% DOP DOUBLE PASS TEST
COMPLIES ANSI/ASHRAE 52.2-2017 STANDARD TEST PROCEDURE
ESP CELL TECHNOLOGY – DUAL STAGE (IONIZER & COLLECTOR)
Number of Cells – VARIES FROM ACTUAL REQUIREMENT
Bag Filters – 1500CFM – 6000 CFM ( AS PER REQUIREMENT)
BMS CONNECTIVITY – MODBUS RS485 PROTOCOL, MONITOR/CONTROL
CONTROL UNIT –
CONTROL PANEL
FAN CONTROL OPERATIONS
ESP HEALTH MONITOR
PRESSURE LOSS MONITOR FOR BAG FILTER MAINTENANCE
INSTALLATION TYPE – WALL & FRAME MOUNT